PT.KARYA AGUNG SOGOSORO: Alat Laboratory - E-Chrom Tech

Alat Laboratory - E-Chrom Tech


A. Chromatography

A01- Gas Chromatography
A02- Liquid Chromatography
A03- Chromatography Data System
A04- On-line Solvent Degassing
A05- HPLC Column Heater
A06- Solvent Recycler
A07- HPLC Filter Holder
A08- Vacuum Manifold

B.Laboratory Equipment :

B01- Spectrophotometer
B02- Ultrasonic Cleaner
B03- Ultrasonic Processor, Hand-held Ultrasonic Processor
B04- Pressure Blowing Concentrator
B05- Magnetic Stirrer
B06- Shaker, Thermo Mixer Incubator, Multi-Tube Vortexer
B07- Peristaltic Pump
B08- Vacuum Pressure Pump
B09- Dry Bath
B10- Water Bath
B11- Shaking Bath
B12- Electronic Balance

C. Accessories

C01- Micro Liter Syringe
C02- Membrane
C03- Syringe Filter
C04- Pipette

C05- Cuvette

A01- GC9800 Gas Chromatography



Descriptions
GC9800 series gas chromatography is a kind of practical analytical instrument with high Performance which allows assembly of highly sensitive thermal conductivity detector (TCD) or highly stable hydrogen flame ionization detector (FID). The design and fabrication of this instrument are based on the principle of gas chromatography. It has reasonable structure, high sensitivity, and it is easy for operation and maintenance.

When operating GC9800, a certain kind of carrier gas (H2, N2, or Ar, which is called mobile phase) is needed. And the stationary phase is filled in the chromatographic column. The compositions of analyzed mixture are separated by multiple distributions between two phases or because of the difference of bulk additive adsorbability they are separated to different compositions. The single composition after chromatographic fractionation enters detector along with the carrier gas one after another. Then the corresponding electric signals will appear in the detector and be recorded with chromatographic data processor or chromatographic working station. Thus qualitative or quantitative analysis can be carried to each composition in mixture.

The instrument can be equipped with different sampling devices and it can be used to analyze gas, liquid and solid samples. In addition, GC9800 can make macro-analysis and micro-analysis for various gases and organic mixtures whose boiling point is below 350ºC. GC9800 is an indispensable analytical instrument in
the fields of petroleum, chemical industry, spice, medicine, hygiene, metallurgy, electric power, gas industry and many specific domains.

Features & Specifications
Different Models of GC9800:
GC9800TP
TCD, double packed column injectors, microcomputer temperature control, three-stage temperature programming, automatic back door open system GC9800FP
FID, packed column and capillary column injector, microcomputer temperature control, three-stage temperature programming, automatic back door open system GC9800FFP
Double FID (double amplifiers), packed column and capillary column injector, microcomputer
temperature control, three-stage temperature programming, automatic back door open system
GC9800TFP
TCD+FID, packed column and capillary column injector, microcomputer temperature control, three-stage temperature programming, automatic back door open system
GC9800 Technique Parameter:
Operation Conditions
Environment temperature: 5-35 ºC
Relative humidity:  85%
Working environment: The room must be free from corrosive gas and hydrogen gas cylinder must be kept away from the fire. There must be no turbulent shock and strong magnetic field, which will affect the operation.
Power supply: 200V ± (5%-10%), frequency: 50Hz ± 0.5Hz
Temperature Control
350ºC ± 0.1ºC; the temperature programming velocity is 0.1-25ºC/min
Susceptiveness of Detector
TCD ( TC-1 ): S  2800mv.ml/mg (benzene)
FID: D 1×10-11g/s (nC16)
Stability
Baseline Shift 30􀈝v/15min, Noise  10v

A02- Liquid Chromatography




Descriptions 
High-pressure Gradient System (with UV230) High-pressure Gradient system (with DAD)A.

The microprocessor controlled speed regulation leads to a very stable speed of the step motor, driving the plungers.Integrated calculation software continuously corrects flow rates according to thesystem pressure.Provide flow rate adjustment function when the actual flow rate is differentfrom the preset.The RS232 remote port is designed to control by data system.SpecificationsFlow range: 0.001-9.999mL/min, with 0.001mL/min incrementFlow accuracy: 􀂔 ± 0.3% (1.000mL/min, 8.5MPa, water, ambient temperature)Flow stability: RSD 􀂔 0.1% (1.000mL/min, 8.5MPa, water, ambienttemperature)Max pressure: 40MPa (0.001-4.999mL/min); 20MPa (5.000-9.999mL/min)Pressure precision: the displayed pressure error is less than ± 0.3%;Pressure pulsation: l 􀂔 1.0%Power requirements: 110/220V, 60/50HzPower consumption: 180WDimensions: 420mm × 280mm × 175mmWeight: 20kgUV230+ UV/Vis DetectorFeaturesDiode Array Technology for wavelength change without any mechanicalmoving parts.Dual lamp (deuterium / tungsten) for a spectral range of 190 - 720 nm.Programmable change of wavelength (up to 5 steps).Serial interface (RS232C) for external control.SpecificationsWavelength range: 190-720nmLight source: Deuterium lamp and Tungsten lampOptical bandwidth: 6nmWavelength accuracy: ±0.5nmWavelength repeatability: ±0.1nmWavelength programmable time setting range: 0.1-999.9minRise Time: 0.0-9.9sLinear range: 􀂕 1.5AU (5%)Baseline noise: 􀂔 ±3 × 10-5 AU (empty cell, 254nm, 1.0s)Baseline drift: 􀂔 5 × 10-4AU/h (empty cell, 254nm, time: 60min)Analytical flow cell :optical path length 10mm; volume 10􀈝LSemi-preparative flow cell: optical path length 3mm; volume 5􀈝LMicro flow cell: optical path length 3mm; volume 1.2􀈝LPower requirements: 110/220V, 60/50HzPower consumption: 110WDimensions: 420mm × 280mm × 175mmWeight: 8kgDAD230 Diode Array DetectorFeaturesA full-closed optical system and quartz light fiber based transmission techniquewas used.High spectral resolution and detect sensitivity were obtained.Combined with the powerful data system (DAD Data System Workstation), theinstrument can provide a lot of information including chromatogram, spectra ofcomponents, three dimension information and peak purity results.SpecificationsWavelength Range:199-618nm (512 Diodes)190-1015nm (1024 Diodes)Light source: Deuterium lamp and Tungsten lampNumber of Diodes: 512/1024Array Resolution: 0.8nmSpectral Resolution: 1.2nmWavelength Accuracy: ±0.5nmWavelength Repeatability: ±0.1nmRise Time: 0.1-9.9sBaseline Noise: < ± 1.5 × 10-5 (AU); N2 in empty cell, 254nm, 1.0sBaseline Drift: < 5 × 10-4 (AU/h) N2 in empty cell, 254nm, time: 60minFlow Cell:Analytical flow cell :optical path length 10mm; volume 10LSemi-preparative flow cell: optical path length 3mm; volume 5LMicro flow cell: optical path length 3mm; volume 1.2LOperating Temperature: 4 to 40°COperating Humidity: < 80%, non-condensingPower requirements: 110/220V, 60/50HzPower Consumption: 110WDimensions: 420mm × 280mm × 180mmWeight: 8kgDAD Data Working StationTo guarantee DAD system a stable operation under Windows 9x, we adoptvirtual driver. With a friendly interface and strong function DADdata-processing platform, users can conveniently observe and process contourmap, spectrogram, chromatogram and three-dimensionalspectrogram-chromatogram. With sufficient functions of chromatographic dataprocessing and quantitative calculating, arbitrary revolving and partsmagnifying, users can obtain more vivid visual effect and results analysis.DAD workstation can provide all kinds of chromatograms, including singlewavelength, arbitrary two-wavelength absorptance, wavelength time procedure,max absorption wavelength and total absorption, and among them, the mostsensitive detection method is max absorption wavelength chromatogram, whilethe best method to quantitate reproducibility is total absorption chromatogram.DAD system provides many discrimination methods on peaks purity, includingcontour map, three-dimensional spectrogram-chromatogram, overlapspectrogram, wavelength comparison diagram and peaks purity calculatingmethod.Users can conveniently built their ultraviolet spectrogram gallery with themultifunctional spectrogram gallery managing and searching procedure, and theprogramme can auto-pick spectrogram to each peak from spectrogram,chromatogram and three dimensional data; auto-search spectrogram gallery;users can also add the auto-picked spectrogram into appointed gallery.7